CAQN OE
Operating Environment Requirements
The components supplied under this contract shall be used in a Class-2 operational environment as defined by MIL-PRF-28800F and MIL-STD-810F with an additional explosive and EMI environmental requirements. All parts, sub assemblies, and end items provided under this contract shall be able to withstand use in the conditions described in, and pass the EMI operational requirements listed below. A description of the environmental conditions the deliverables must be able to pass is listed in table 2. The table below calls out which specific requirements and class of testing the parts must be able to withstand and still operate within specification. A certificate of Conformance shall be provided with each shipment of parts that confirms that the parts meet the performance specification for the specified operational environment. A certificate which meets the requirements of Clear Align quality note FZ shall be provided with each shipment.
SUMMARY OF ENVIRONMENTAL REQUIREMENTS (MIL-PRF-28800F UNLESS OTHERWISE NOTED)
Environmental Condition
|
Class/Required Tests
|
Temperature, not operating
|
2
|
Temperature, operating
|
2
|
Relative humidity
|
2
|
Altitude, not operating
|
2
|
Altitude, operating
|
Not required
|
Vibration limits
|
2
|
Bounce, loose cargo
|
2
|
Shock, functional
|
2
|
Transit drop
|
2
|
Bench handling
|
2
|
Shock, high impact
|
2
|
Watertight
|
Not required
|
Splash proof
|
2
|
Drip proof
|
Not required
|
Fungus resistance
|
Not required
|
Salt exposure, enclosure
|
2
|
Explosive atmosphere
|
Required
|
Dust resistance (case)
|
Required
|
Solar radiation
|
Not required
|
Electromagnetic Compatibility (EMC)
|
MIL-STD-464A; and MIL-STD-461E (Table V), RE101, RE102, RS101, and RS103
|







Explosive Atmosphere Test Description